HIPAA does not certify software or prescribe a tech stack. It requires that anyone who creates, receives, maintains or transmits electronic protected health information (ePHI) for a covered entity protect it with administrative, physical and technical safeguards, and be able to prove they did. If you are building or buying software for a clinic, health plan or healthcare vendor, those safeguards are your requirements list.
This guide turns the regulation into engineering terms: who is covered, what the technical and administrative safeguards demand, a checklist you can hand to a development team, and the mistakes we see most often.
TL;DR
- HIPAA applies to covered entities and their business associates. If your software handles ePHI on behalf of one, you are in scope and need a signed business associate agreement (BAA).
- The rule is technology-neutral. It names outcomes (confidentiality, integrity, availability), not products, so you must document your choices.
- Technical safeguards in 45 CFR 164.312 cover access control, audit controls, integrity, authentication and transmission security.
- Administrative safeguards, above all a documented risk analysis, are where most software projects fall short.
- A proposed Security Rule update is pending but not final. Build to it anyway.
Table of Contents
- Who HIPAA applies to, and when your software is in scope
- What “HIPAA compliant software” actually means
- Technical safeguards: the engineering requirements
- Administrative safeguards: where projects usually fail
- Business associate agreements are working documents
- A HIPAA software checklist you can hand to your developers
- Small practices have the same duties
- What is changing: the proposed Security Rule update
- Our perspective: compliance is a design input, not a final review
- How we can help
- FAQ
- Sources
Who HIPAA applies to, and when your software is in scope
The rules cover health plans, healthcare clearinghouses, and providers who conduct certain electronic transactions, plus their business associates. A business associate is any entity that performs activities involving ePHI on a covered entity’s behalf. That includes a software company hosting patient data, a vendor running an AI tool over clinical notes, and a consultancy with access to production records.
Not every health app is covered. HHS says an app provided by or on behalf of a covered entity that handles ePHI for it makes the developer a business associate. An app an individual picks on their own to receive their own records is generally outside HIPAA. Whether a BAA is needed depends on the relationship between the app developer and the covered entity.
A quick test: if a provider, plan or their vendor pays for or deploys your product, and patient data flows through it, assume you are a business associate until counsel says otherwise.

What “HIPAA compliant software” actually means
There is no federal seal. HHS’s Security Rule summary describes a national set of standards organized into administrative, physical and technical safeguards. Software can support compliance, but compliance belongs to the organization using it.

The rule is also flexible by design. A five-person practice and a hospital network must meet the same goals of confidentiality, integrity and availability, but their implementations will look very different. The catch: you must show your reasoning in a documented risk analysis. Being unable to demonstrate that is a common thread in enforcement according to our research of HHS material.
Technical safeguards: the engineering requirements
The technical safeguards live in 45 CFR 164.312. HHS defines them as the technology, and the policies and procedures for its use, that protect ePHI and control access to it. Here is how each standard translates into a build.
| Standard | What it asks for | What it means in practice |
|---|---|---|
| Access control | Unique user identification and emergency access procedure (required); automatic logoff and encryption (addressable) | Individual accounts, no shared logins, role-based permissions, session timeouts, a documented break-glass process |
| Audit controls | Mechanisms that record and examine activity in systems holding ePHI | Immutable logs of who viewed, changed or exported which record, and a process to review them |
| Integrity | Protect ePHI from improper alteration or destruction | Checksums, versioned records, controlled write access, tested backups |
| Person or entity authentication | Verify that whoever seeks access is who they claim | Strong passwords, multi-factor authentication, service-to-service credentials |
| Transmission security | Guard against unauthorized access to ePHI in transit | TLS on every connection, including internal service traffic and APIs |
Required versus addressable
“Addressable” does not mean optional. An entity must assess whether a specification such as encryption or automatic logoff is reasonable and appropriate for its environment. If it is not, it must document why and implement an equivalent alternative. In practice, nearly every modern system should encrypt ePHI at rest and in transit, because a documented reason to skip it is hard to write.
Decisions your team will face
- Logging without leaking. Audit logs need enough detail to reconstruct access, but application logs, error trackers and analytics tools must not capture patient names or record contents. Masking is an engineering task, and our piece on PII data masking failures covers the use cases.
- Emergency access. Someone must be able to reach records when the normal path fails. Design it, restrict it, log it.
- Third-party services. Every service that touches ePHI, from email to error monitoring to an AI model API, needs its own BAA or has to be kept away from ePHI entirely.
Administrative safeguards: where projects usually fail
Software teams tend to read only the technical section. Administrative safeguards are the policies, workforce rules and processes that sit around the code. The one that matters most is the risk analysis: an accurate, thorough assessment of risks to the confidentiality, integrity and availability of ePHI, followed by a risk management plan.
For a software project, the administrative side translates into these deliverables:
- A risk analysis covering the whole environment, not just the application: hosting, devices, vendors, backups, support staff access.
- Role definitions and access reviews. Who gets production access, who approves it, how it is removed when someone leaves.
- A contingency plan. Backups, disaster recovery and a tested restore process.
- Incident response. Business associates must identify and respond to suspected or known security incidents and report to the covered entity.
- Workforce training and sanctions for people who touch the system.
- Vendor management, including BAAs that actually work, covered below.
These documents are what an auditor asks for first. Our HIPAA compliance checklist goes into the evidence side of audit readiness.
Physical safeguards
If you host in a major cloud, the data center controls sit with the provider, but device and workstation policies stay with you: laptops with access to ePHI, screen locks, disposal of old hardware, and remote work rules.
Business associate agreements are working documents
A BAA is not paperwork to sign and file. HHS notes that a BAA can and should define the expected response times, frequency and level of detail for security incident reports. If yours is silent on that, you will be negotiating during an incident.
Two misconceptions deserve a direct answer, both from HHS cloud guidance:
- “We only store encrypted data, so we are not a business associate.” Wrong. Not holding the decryption key does not exempt a cloud provider that maintains ePHI for a covered entity. A cloud service is generally not a mere conduit like the postal service.
- “Our cloud provider is compliant, so we are.” Compliance is shared. The covered entity still owns the risk analysis for the whole environment and must make sure its BAAs cover every service in use.
For the contract side, see our note for compliance officers on business associate agreements and OCR risk.
A HIPAA software checklist you can hand to your developers
Use this as a starting point for scoping. It is not legal advice, and your compliance officer or healthcare counsel should confirm it against your situation.
Before you build
- Decide whether you are a covered entity or business associate, and sign BAAs with customers and subprocessors.
- Map every place ePHI is created, stored, transmitted or logged.
- Complete the risk analysis and keep it current.
In the architecture
- Unique user IDs, role-based access, multi-factor authentication.
- Encryption at rest and in transit, with key management documented.
- Automatic session timeout and an emergency access procedure.
- Audit logging with a review process and protected log storage.
- Separate development, test and production, with no real patient data in test environments.
In operations
- Tested backups and a written disaster recovery plan.
- Incident response runbook and BAA-defined reporting windows.
- Access reviews on a schedule, and prompt deprovisioning.
- Workforce training records.
For breaches
- The Breach Notification Rule requires notice to individuals without unreasonable delay and no later than 60 days after discovery. Your runbook should assume that clock starts at discovery.
Small practices have the same duties
Size changes how you implement, not whether you do. Even a specialty clinic handling billing, HSA and FSA claims and patient paperwork creates records that fall under the rules; a practical example is how a chiropractic office has to keep HSA and FSA documentation audit-ready. The same discipline applies to the software holding those records: know where the data sits, who can see it, and how you would prove it.
What is changing: the proposed Security Rule update
HHS issued a Security Rule notice of proposed rulemaking on December 27, 2024 to give covered entities and business associates more specific instructions. OCR’s director tied the proposal to a surge in cyberattacks, with ransomware a central concern. The current standards remain in effect. Secondary reporting says the rule is still proposed, not final, as of mid-2026, so check HHS for the latest before you rely on that.
The backdrop is stark. HHS’s report to Congress notes that over 167 million individuals were affected by large healthcare breaches in 2023, a record, with hacking and ransomware growing fastest. Our advice: design to stronger practice than the 2013-era text requires. Retrofitting later costs more than building it in.
Our perspective: compliance is a design input, not a final review
We build healthcare software, and the projects that go smoothly share one trait: compliance was discussed in the first week, not the last. Teams that treat HIPAA as a sign-off step discover in testing that their logs contain patient names or that a third-party tool has no BAA. Both are expensive to unwind.
Our approach starts with discovery. We map where ePHI will live, who touches it and which vendors are involved before anyone writes code. That map becomes the backbone of the risk analysis and the architecture. We bring engineers with big tech experience to the work, and we position ourselves as a strategic partner, not just a code provider.
We also push back on the idea that compliance can be bought. No cloud provider, framework or AI platform makes you compliant. They give you infrastructure and controls; you still own the documentation, the access decisions and the incident plan. For a deeper look, read the reality of building HIPAA-ready systems.
— Cameron
How we can help
If you are scoping a healthcare product or checking whether an existing system holds up, our Discovery Audit is a $999 one-off engagement, and it is credited toward a build contract. For a look at what we build for providers, see AiRN and our HIPAA-compliant patient portal case study. Typical project ranges are on our custom software cost guide: $10,000 to $50,000 for an MVP or simple app, and $50,000 to $150,000 for a mid-complexity platform.
FAQ
Does HIPAA require specific software or encryption standards?
No. The Security Rule is technology-neutral and sets outcomes rather than products. Encryption is an addressable specification, which means you must assess it and document your decision, but most organizations should treat it as expected.
Is there an official HIPAA certification for software?
No federal body certifies software as HIPAA compliant. Vendors who advertise a certificate are offering their own assessment or a third-party attestation. Ask for the risk analysis, policies and BAA instead.
Do I need a BAA with my cloud provider?
If the provider creates, receives, maintains or transmits ePHI for you, generally yes, even when the data is encrypted and the provider lacks the key. HHS’s cloud guidance also says the BAA should cover every service you use, so check that it does.
Are health and wellness apps covered by HIPAA?
Only when provided by or on behalf of a covered entity, or built as a service for one. An app a person chooses to receive their own records is generally outside HIPAA, though other laws may still apply. Confirm your case with healthcare counsel.
Sources
- HHS Annual Report to Congress on HIPAA compliance, calendar year 2024
- The access right, health apps and APIs, HHS
- BAA and app designated by the individual, HHS FAQ
- Summary of the HIPAA Security Rule, HHS
- HHS
- 45 CFR 164.312 Technical safeguards, eCFR
- HIPAA Security Series #4: Technical Safeguards, HHS
- CSP security incident reporting FAQ, HHS
- Guidance on HIPAA and cloud computing, HHS
- CSP as conduit FAQ, HHS
- Breach Notification Rule, HHS
- HIPAA Security Rule NPRM, HHS
- 2026 HIPAA Updates, MetricStream